28 UDC 6300 Process Controller Product Manual 1/03
3.2 Configuration Prompts
Diagram: prompt
hierarchy
Figure 3-1 shows an overview of the UDC 6300 Set Up prompts and their
associated Function prompts. (Read from left to right.)
Figure 3-1 Overview of UDC6300 Prompt Hierarchy
Function
TUNING
• Press [SET UP] key to access the Set Up prompts
• Press [FUNCTION] key to access Function prompts within each Set Up group. • • •
Continued from
previous line
Set Up
GAIN VALn MAN RSET
PROP BD2
or GAIN2
RATE2MIN
RSET2MIN
RSET2RPM
CYCLE SEC
TUNING L2
GAIN VALn MAN3RSET
PROP BD4
or GAIN4
RATE4MIN
RSET4MIN
RSET4RPM
CYC3SEC
SP RAMP
SP CHANGE
ALGORTHM
OUT OVRD IN ALG 1 CONSTNT K CALC HIGH CALC LOWCONTR ALG
ALG2 IN A 8SG CHAR1 Xn VALUE Yn VALUE
ADV MATH
GATEnTYPE GATEn INB GATEn OUTRepeated for 5 (n) Gates
OUT ALG 4–20 RNG
INPUT 1
IN1 HIGH BIAS IN1 FILTER 1
INPUT 2
IN2 HIGH BIAS IN2 FILTER 2
INPUT 3
IN3 HIGH BIAS IN3 FILTER 3
INPUT 4
IN4 HIGH BIAS IN4 FILTER 4
INPUT 5
IN5 PULSE IN5 LOW RATIO IN5 BIAS IN5 FILTERIN5 BURNOUT5
CONTROL
PID SETS RSP SRC AUTO BIAS SP TRACK PWR MODE SP HI LIM
Continued from
previous line
I HILIM DEADBAND OUT HYST FAILMODE FAILSAFE PBorGAIN
CONTROL2
RSP SOURC AUTO BIAS SP TRACK
Continued from
previous line
PID SETS
SP HILIM
FAILMODE FAILSAFE
DIG1 COMB4mA VAL DIG IN 2 DIG2 COMB
ACCUTUNE
OPTIONS
COM
ADDRESS OP1 ADDR
PV2 ADDR
OP2 ADDR PARITY
Continued from
previous line
ALARM
A1S2 VALU
PROP BD
or GAIN
PROP BD3
or GAIN
FUZZY
LOOP RATE
LOG GATES
OUT ALG
XMITTER 1
XMITTER 2
XMITTER 3
XMITTER 4
IN5 TYPE
PV SOURCE
PV2 SRC
CUR OUT 2
COMSTATE
A1S1 VALU
RATE MIN
RATE3MIN
PROC GAIN
PID LOOPS
ALG2 IN B
GATEn INA
OUT2 ALG
IN1 LOW
IN2 LOW
IN3 LOW
IN4 LOW
XMITTER5
SW VALUE
I LOW LIM
SW VALUE
DROPOFF
20mA VAL
ADDRESS2
A2S1 VALU
RSET MIN
RSET RPM
RSET3MIN
RSET3RPM
ACCUTUNE
CONT2ALG
ALG2 IN C
GATEn K
DO STATE
RATIO 1
RATIO 2
RATIO 3
RATIO 4
IN5 HIGH
LSP's
DROPOFF
LSP's
DEADBAND
DIG IN 1
PV1 ADDR
A2S2 VALU
USED FOR FIELD CALIBRATION
DISPLAY DECIMAL2 SP GRAPH 2LOOP DIS ID TAG PV TAG PV TAG 2
CALIB
STATUS
DECIMAL
VERSION
FAILSAFE
TEMPUNIT
FAILSF 2
PWR FREQ
RAM TEST CONFTEST NV TEST CALTEST FACT CRC
SP RAMP FINAL SP SP RATETIME MIN RATE UP RATEUP2 RATEDWN2RATE DWN
DEADTIME3
I LOLIM
SP LOLIM
BAUD
RCASOPT1 SHED2MODE SHED2SP CSP2RATIO CSP2BIAS RCASOPT2 LOOPBACK
CRITERIA
8SG CHAR2
Xn
VALUE2
DIG IN 3
DIG IN 4
A1S1 HorL
Continued from
previous line
A1S2 HorL
A3S1 VALU A3S2 VALU A4S1 VALU A4S2 VALU A1S1 TYPE
A2S1 HorL A2S2 HorL A3S1 HorL A3S2 HorL A4S1 HorL A4S2 HorL
SP CHANG2PROCGAIN2ACCUTUNE2 CRITERIA2
Continued on next page