1/03 UDC 6300 Process Controller Product Manual 109
4.10 Input 5 Parameters Set Up Group, Continued
Table 4-9 Input 5 Group Definitions, continued
Lower Display
Prompt
Upper Display
Range of Setting
or Selection
Parameter
Definition
XMITTER 5
B TC
E TC
J TC
K TC
NNM
NIC TC
R TC
S TC
T TC
W TC
100 PT
100 LO PT
200PT
500PT
LINEAR
SQ ROOT
TRANSMITTER CHARACTERIZATION - This
selection lets you instruct the controller to
characterize a linear input to represent a non-linear
one.
B TC - B Thermocouple
E TC- E Thermocouple
J TC- J Thermocouple
K TC- K Thermocouple
NNM- NiNiMo Thermocouple
NIC TC- Nicrosil Nisil Thermocouple
R TC- R Thermocouple
S TC- S Thermocouple
T TC- T Thermocouple
W TC- W Thermocouple
100 PT - 100 Ohm RTD High
100 LOW - 100 Ohm RTD Low
200PT- 200 Ohm RTD
500PT- 500 Ohm RTD
LINEAR - Linear*
SQ ROOT - Square Root*
*no characterization
IN5 HI
–999 to 9999
in Engineering units
INPUT 5 HIGH RANGE VALUE in engineering units
is displayed for Input 5 but can only be configured for
linear, square root, or pulse actuations only.
IN5 LO
–999 to 9999
in Engineering units
INPUT 5 LOW RANGE VALUE in engineering units
is displayed for Input 5 but can only be configured for
linear, square root, or pulse actuations only.
RATIO IN5
–20.00 to +20.00
INPUT 5 RATIO VALUE - Select the ratio value for
Input 5.
BIAS IN5
–999 to 9999
in Engineering units
INPUT 5 BIAS VALUE - Select the bias value for
Input 5.
FILTER IN5
0 to 120 seconds
No filter = 0
FILTER FOR INPUT FIVE— A software digital filter
is provided for input 5 to smooth the input signal.
You can configure the first order lag constant from 1
to 120 seconds. If you do not want filtering, enter 0.
Table 4-9 continued on next page