First Time Installation to Initialize Dialer
STEP 1 Apply power to the unit. The LCD will read: NOT PROGRAMMED PRESS KEYPAD #1.
STEP 2 Press 1. The LCD will change to read: USP AD2000 X.X
then: PROGRAM: NUMBERS
then: SELECT: 1-8
0(DONE)
Programming Example for Quick Setup
Before programming the dialer, study the example shown in the “Sample Program Planner” section
of this appendix.
This sample demonstrates programming in one telephone number, two numeric pager numbers,
two attempts, two repeats, an ID plus two additional OGMs, and channels 1 and 4.
Once you understand the setup, use the blank “Program Planner” sheet in this appendix to begin
programming your dialer. We recommend making several blank copies of the “Program Planner”
before beginning the process.
STEP 1 Press M repeatedly until the LCD reads: USP AD2000 X.X, wait a few seconds until LCD
reads: Program: Numbers; 1(yes) 2(no). Press 1.
STEP 2 When the LCD reads SELECT 1-8, press 1 to install the first phone number in location 1.
Press 2 to indicate no pager; then press, in sequence, (fictitious) phone number 2345678 followed
by the “*” sign to store the programming process for that number.
STEP 3 Press 5 to install the second phone number in location 5; press 1 to indicate numeric pager;
then press’ in sequence, 3456789PP4455# followed by the “*” sign. The first seven digits represent
the pager number dialed; each P stands for a 2-second pause; the next four digits followed by the #
sign represent the pager code and the * stores the programming process for that number.
Now press 6 to install the third phone number in location 6 and press 1 to indicate numeric pager.
Press, in sequence, 3456789PP5544# followed by the “*” sign.
STEP 4 Press 0 to exit PROGRAM NUMBERS.
STEP 5 At the PROGRAM: T-LINE prompt, press 1 (yes) to program. Press 1 to choose tone; press
2 to indicate no PBX; press 2 to program in two dialing attempts per emergency number called;
press 2 to program in two message repeats for each call.
STEP 6 Press 1 (yes) to PROGRAM OGM(S). Press 2 three times to Scroll to option #4: ID, 2
OGMS; press 1 to program in an ID message and two specific outgoing messages (OGMs).
STEP 7 Using a prepared script and speaking six-to-eight inches from the dialer’s microphone on
the front of the unit, press R when you are ready to enunciate your 15-second identification
message and your two 18-second messages. Dialer automatically prompts to next OGM. Make
OGM1 a message informing the receiving party of the cellular repeater fault. Make OGM2 a message
to dispatch a technician to the site.
STEP 8 Press 1 to play back all recorded messages; press 1 again to accept.
NOTE: DIALER LCD WILL ONLY SHOW PROGRAMMED NUMBERS AND OGM OPTIONS.
STEP 9 Press 1 to PROGRAM CHANNELS.
STEP 10 Press 1 to program Channel 1. Press 1 to ENABLE. Press 1 then enter 60 then
press “*” for a 60-second EXIT delay; press 1 then enter 60 then press “*” for a 60-second entry
delay.